EcoStar E-Series Inverter is now available in four exclusive models: E-840i (300Watts), E-1040i (600Watts),E-1240i/E-720i (720Watts) & E-1440i (1440Watts). A reliable solution to load shedding problem, E – Series Inverter features modern sine waves offering full battery polarity protection and enhanced battery charging.
Load calculation based on:
Technical
| ||||||||
Environment
| ||||||||
Input
| ||||||||
Output
| ||||||||
Battery
| ||||||||
Alarm
| ||||||||
Protection
| ||||||||
Operating Environment
|
EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.
900 W
Single phase 2 wires and Ground
110VAC – 290VAC 110-160VAC on 30% load, 160-200VAC on 80% load 200-290VAC on 100% load
45Hz-55Hz(Auto Detect)
>0.99
<7%(100% nonlinear load)
Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%
Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%
Support
±2%
Single Phase & Ground
200/208/220/230/240VAC
Pure sine wave
0.9
50Hz or 60Hz (Synchronized to Mains)
50Hz/60Hz ±0.02Hz
3:1
<3% with linear load <5% with non linear load
36VDC
Full load.3-5 min(Standard) Estimated remaining time displayed on the LCD
12V/7AH
0°C~40°C
-25°C~55°C
0~95% non condensing
Load150% : 300mS then shut
Load Less Then 100% – 150% : 30Seconds, Greater Then 150% : 300mS then shut
Supports Windows family, Linux, FreeDSB etc.
SNMP card, Dry Contact card
Built in Power Surge, Lightning Device
Up to 89%
>94%
440×86.5×410
12
IEC320 C14-10A
IEC320 C13-10Ax6
Anderson like PowerPole Modular connectors
CE,CB
10000 W
9600 W
3-phase in / 3-phase out
-10 to 55°C
0 ~ 90% RH (No condensing)
0 ~ 1000 m*
622 x 500 x 167.5
45
Optional SNMP, Modbus, and AS-400 cards available
14850W
720 VDC / 900 VDC
350 VDC ~ 850 VDC
2 / 2 x 18.6A
230 VAC (P-N) / 400 VAC (P-P)
184 – 265 VAC per phase
> 96%
> 95%
120 – 140 VAC per phase / 180 VAC per phase
25A
170 – 280 VAC per phase
900 VDC
Pure Sinewave
91%
320 VDC / 350 VDC
48 VDC
Default 60A, 5A – 200A (Adjustable)
120 – 140 VAC per phase / 180 VAC per phase
350 VDC ~ 850 VDC
2 / 2 x 18.6A
25A
170 – 280 VAC per phase
230 VAC (P-N) / 400 VAC (P-P)
720 VDC / 900 VDC
320 VDC / 350 VDC
350 VDC ~ 850 VDC
2 / 2 x 18.6A
RS-232/USB and CAN Interface
> 0.99
230 VAC (P-N) / 400 VAC (P-P)
14.5 A per phase
14.5 A per phase
184 – 265 VAC per phase
91%
EcoStar ESM Series is a unique inverter of its kind that provides a complete and permanent solution to power outage. Based on pure sine waves ESM Series is very energy efficient and generates maximum power output. The Series offers smart solutions from 600VA (480 W) to 1500VA (1200 W).
Load calculation based on:
480 W
Inverter Mode : 120-300VAC/Smart Mode: 145-285VAC
220VAC
50Hz
Single Phase
38~70Hz
Inverter Mode : 160-260V / Smart Mode : 190-260V
220VAC ± 10%
Inverter Mode : 160-260V / Smart Mode : 190-260V
50HZ±1HZ
Tracking Utility
Sine Wave
0.8
? 6ms
12VDC
13.8V±0.3V
10A/20A
0?C ~ 40?C
20% ? 95%?Non?Condensing
11.4/12.7
272 x 285 x 165
380 x 375 x 255
Overload/Short circuit /Overheat
EcoStar E-Series Inverter is now available in four exclusive models: E-840i (300Watts), E-1040i (600Watts),E-1240i/E-720i (720Watts) & E-1440i (1440Watts). A reliable solution to load shedding problem, E – Series Inverter features modern sine waves offering full battery polarity protection and enhanced battery charging.
Load calculation based on:
1440 W
230Vac
170-280Vac for Narrow Range Mode 90-280Vac for Wide Range Mode
50/60Hz (Auto Sensing)
±10%
50Hz ± 1Hz
<20ms
Simulated Sine Wave
24V
10A/20A
Overload, Overcharge & Deep Discharge Protection
Beep every 2 seconds
Beep every 0.5 seconds
Continuous Beep
0-90% RH @ 0-40°C (Non-Condensing)
Less then 40dB