Loading
  • NL-series-600x600

    EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.

    2700 W

    440×86.5×410

    26.6

    Anderson like PowerPole Modular connectors

    IEC320 C20-16A

    IEC320 C13-10Ax8 & C19-16Ax1

    0°C~40°C

    <1500m

    -25°C~55°C

    0~95% non condensing

    <50dB(at 1 meter)

    110VAC – 290VAC 110-160VAC on 30% load, 160-200VAC on 80% load 200-290VAC on 100% load

    45Hz-55Hz(Auto Detect)

    >0.99

    <7%(100% nonlinear load)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Support

    Single Phase 2 Wires and Ground

    ±2%

    Pure sine wave

    > 0.99

    Single Phase & Ground

    200/208/220/230/240VAC

    50Hz or 60Hz (Synchronized to Mains)

    50Hz/60Hz ±0.02Hz

    3:1

    <3% with linear load <5% with non linear load

    72VDC

    Full load.3-5 min(Standard) Estimated remaining time displayed on the LCD

    12V/9AH

    Load less then 100% – 150% : 30Seconds, greater then 150% : 300mS then shut

    Load Less Then 100% – 150% : 30Seconds, Greater Then 150% : 300mS then shut

    Built in Power Surge, Lightning Device

    Up to 90%

    >94%

    CE,CB

  • NL9-RT-10K

    EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.

    9000 W

    208-478Vac OR 120VAC-276VAC

    40Hz-70Hz

    >0.99

    <5%(100% nonlinear load)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%)

    Support

    3 phase 4 wires and Ground OR Single Phase & Ground

    ±2%

    Pure sine wave

    0.9

    Single Phase & Ground

    220/230/240VAC

    3:1

    <2% with linear load <5% with non linear load

    192Vdc,216Vdc,240Vdc

    Full load>2min(Standard) Estimated remaining time displayed on the LCD

    12V/9AH

    0°C – 40°C

    <1500m

    -25°C~55°C

    0~95% non condensing

    <60dB(at 1 meter)

    Load <110%: 3min, <125%:

    Load <110%: 30S, <125%: 1S, <150%:

    USB,R 485,SNMP(Optional)

    USB,R 485,SNMP(Optional)

    USB,R 485,SNMP(Optional)

    >90%

    >97%

    441×131(3U)x580

    25

    Hardwire

    Hardwire

    Hardwire

    CE,EN/IEC 62040,EN/IEC 62040-1-1

  • NL9-RT-6K

    EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.

    5400 W

    208-478Vac OR 120VAC-276VAC

    40Hz-70Hz

    >0.99

    <5%(100% nonlinear load)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%)

    Support

    3 phase 4 wires and Ground OR Single Phase & Ground

    ±2%

    Pure sine wave

    0.9

    Single Phase & Ground

    220/230/240VAC

    3:1

    <2% with linear load <5% with non linear load

    192Vdc,216Vdc,240Vdc

    Full load>2min(Standard) Estimated remaining time displayed on the LCD

    12V/7AH

    0°C~40°C

    <1500m

    -25°C~55°C

    0~95% non condensing

    <60dB(at 1 meter)

    Load <110%: 3min, <125%:

    Load <110%: 30S, <125%: 1S, <150%:

    USB,R 485,SNMP(Optional)

    USB,R 485,SNMP(Optional)

    USB,R 485,SNMP(Optional)

    >90%

    >97%

    441×131(3U)x580

    23

    Hardwire

    Hardwire

    Hardwire

    CE,EN/IEC 62040,EN/IEC 62040-1-1

  • NL9-RT-(2K)

    EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.

    1800 W

    Single Phase 2 Wires and Ground

    110VAC – 290VAC 110-160VAC on 30% load, 160-200VAC on 80% load 200-290VAC on 100% load

    45Hz-55Hz(Auto Detect)

    >0.99

    <7%(100% nonlinear load)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Support

    ±2%

    Pure sine wave

    0.9

    Single Phase & Ground

    200/208/220/230/240VAC

    50Hz or 60Hz (Synchronized to Mains)

    50Hz/60Hz ±0.02Hz

    3:1

    <3% with linear load <5% with non linear load

    72VDC

    Full load.3-5 min(Standard) Estimated remaining time displayed on the LCD

    12V/7AH

    0°C~40°C

    <1500m

    -25°C~55°C

    0~95% non condensing

    <50dB(at 1 meter)

    Load less then 100% – 150% : 30Seconds, greater then 150% : 300mS then shut

    Supports Windows family, Linux, FreeDSB etc.

    SNMP card, Dry Contact card

    Built in Power Surge, Lightning Device

    Up to 90%

    >94%

    440×86.5×620

    22

    IEC320 C20-16A

    IEC320 C13-10Ax8

    Anderson like PowerPole Modular connectors

    CE,CB

    Load Less Then 100% – 150% : 30Seconds, Greater Then 150% : 300mS then shut

  • NL9-RT-1K

    EcoStar NL9 Series is a UPS designed with high intensive technology that provides wide input voltage range and is very high efficient. NL9 Series acts as a reliable and high quality perfect partner during electricity failure and offers energy solutions from 1kva to 10kva.

    900 W

    Single phase 2 wires and Ground

    110VAC – 290VAC 110-160VAC on 30% load, 160-200VAC on 80% load 200-290VAC on 100% load

    45Hz-55Hz(Auto Detect)

    >0.99

    <7%(100% nonlinear load)

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Max.voltage: +15%(optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10%

    Support

    ±2%

    Single Phase & Ground

    200/208/220/230/240VAC

    Pure sine wave

    0.9

    50Hz or 60Hz (Synchronized to Mains)

    50Hz/60Hz ±0.02Hz

    3:1

    <3% with linear load <5% with non linear load

    36VDC

    Full load.3-5 min(Standard) Estimated remaining time displayed on the LCD

    12V/7AH

    0°C~40°C

    -25°C~55°C

    0~95% non condensing

    Load150% : 300mS then shut

    Load Less Then 100% – 150% : 30Seconds, Greater Then 150% : 300mS then shut

    Supports Windows family, Linux, FreeDSB etc.

    SNMP card, Dry Contact card

    Built in Power Surge, Lightning Device

    Up to 89%

    >94%

    440×86.5×410

    12

    IEC320 C14-10A

    IEC320 C13-10Ax6

    Anderson like PowerPole Modular connectors

    CE,CB